Should the flow meter in the heat transfer oil heat meter be installed in the flow pipe or the return pipe? What is the impact on the measurement results?

Should the flow meter in the heat transfer oil heat meter be installed in the flow pipe or the return pipe? What is the impact on the measurement results?

The operation principle of Guangzhou Dichuan Instrumental Thermal Oil Heat Meter is: the heat meter installed in the heat exchange system, when the heat carrier flows through the system, according to the flow given by the flow sensor, the oil given by the paired temperature sensor, back The oil temperature, as well as the time the heat carrier heat transfer oil flows, is calculated by the calculator and displays the amount of heat released or absorbed by the system. The basic formula is:

Where Q is the heat released by the heat meter in the heat exchange system, in units of KJ ;

Qm—— mass flow rate of heat transfer liquid flowing through the heat meter, unit KG/S ;

Δh—— the ratio of the enthalpy difference of the heat transfer liquid corresponding to the inlet temperature and the outlet temperature in the heat exchange system, unit KJ/KG ;

t - time, unit s .

From this equation, in a heat exchange system, heat is the integral of the change in the enthalpy of the influent and return water of the heat exchange system during time t . The enthalpy value depends on the temperature, pressure and specific heat capacity of the heat carrier. The original physical quantity that can be measured by a heat meter is the temperature and flow rate of the heat carrier, and the flow meter measures the volume flow rate, not the mass flow rate. Moreover, the specific gravity of the heat carrier varies with temperature, so it must be To make corrections, this leads to another calculation formula, as follows:

Where Q is the heat released by the heat meter in the heat exchange system, in units of J or KW.H ;

V—— the cumulative volume flow of the superheat energy meter of the heat transfer liquid flow, in m3 ;

Δθ— the temperature difference at the inlet and outlet of the heat transfer liquid in the heat exchange system, in °C ;

K—— thermal coefficient, which is a function of the heat transfer liquid under the corresponding temperature, temperature difference and pressure, in units of J/m3 or KW.H/m3 °C

This formula is the "K- factor calculation method " . The K factor is divided into the oil heat coefficient and the oil return heat coefficient. Its physical meaning is: the heat released per one cubic degree of heat carrier per cubic meter of heat carrier in the oil inlet or return port after flowing through the heat exchange system .

So far, the European advanced level of heat meter products and design reports have been used to correct the measurement accuracy by using the K- factor method. Obviously, the value of the K factor depends on the volume of the heat meter. The flow meter is installed in the system of the inlet or the return port. Even under the same temperature difference, the installation position of the volume flowmeter must be studied. Let us give an example: when the inlet temperature is 70 degrees, the return port temperature is 30 degrees, and the pressure is 16 bar , when the flowmeter is installed on the return line, K=1.156462 (the European standard calculation result is 1.1565) ), and when installed on the inlet pipe to the upper calculation, K = 1.135530 , the difference is close to 2% . If the inlet pipe temperature is 130 degrees and the return pipe temperature is 70 degrees, the error can reach 4.4% , which obviously exceeds the allowable error range. Therefore, when the K- factor method is used to calculate the heat, there is a strict requirement for the installation position of the flow meter, and the installation on the oil discharge pipe cannot be easily installed on the oil return pipe. Guangzhou Dichuan Instrument & Meter Co., Ltd. is mainly engaged in the research and development and production of flow meters. Mainly engaged in: electromagnetic flowmeter, vortex flowmeter, turbine flowmeter, V- cone flowmeter, rotameter, sewage flowmeter, electromagnetic flowmeter, turbine flow Meter, vortex flowmeter, ultrasonic flowmeter, MF type gas flowmeter   , FS series micro-miniature flowmeter, gas mass flowmeter, sewage flowmeter, gear flowmeter, environmental analysis instrument COD ammonia nitrogen instrument   Dissolved oxygen instrument, PH meter, conductivity, resistivity, residual chlorine   Dichuan Instrument, such as secondary water supply analysis system, has won extensive market support with domestic leading technical level and perfect after-sales service. We sincerely invite customers to come to discuss cooperation and are willing to work with you to win the future.

Rubber Reinforced Type Instant Adhesive

Rubber Reinforced Type Instant Adhesive is a single-component ,no mixing Cyanoacrylate Adhesive.Fast curing speed,able to achieve bond strength in a short time.Good bonding effect on rubber, metal, plastic and other materials.The cured adhesive layer has a certain degree of flexibility and elasticity and can withstand impact and vibration.
Characteristics of rubber reinforced type instant adhesive:
1. Fast curing speed: It can be cured quickly in a short time, and the initial curing can usually be achieved within a few seconds to tens of seconds, which improves production efficiency.
2. High bonding strength: It has a remarkable bonding effect on rubber and other materials (such as metal, plastic, etc.), and can firmly bond parts of different materials together.
3. Good flexibility: After curing, the adhesive layer has good flexibility. When the bonded parts are subjected to external forces (such as bending, twisting, stretching, etc.), the adhesive layer will not easily break, effectively protecting the bonded parts, especially It is suitable for the bonding needs of rubber, a material that has a certain elasticity.

cyanoacrylate adhesive for rubber,rubber toughened cyanoacrylate,super glue for rubber,flexible super glue for rubber

Dongguan Shuangzhan Industrial Co.,Ltd , https://www.lingwogroup.com