Innovative structure with patents,employs small desiccant chamber unit
1.Air flow equally and evenly pass through each desiccant chamber
2.Avoid channelling effect which more likely happens in traditional desiccant dryer
3.Small chamber allow no mandatory annul inspection
4.Molecular sieve capability is much better than Alumina and silicon desiccant in traditional dryer
5.PLC controller ,Full function touch panel control

Structure and operation
Biteman dryer have two groups of desiccant chambers,A and B ,according to flow rate,A and B shift between adsorption and regeneration

Ease of replacement of desiccant chambers,it can't be more simpler comparing to exchange of desiccant,only one wrench it is done.Further more,needn't worry the desiccant density after refilling because it is filled in our factory to keep constant and stable pressure dew point,just like new dryer from factory


For more
B-series            Heatless        (-40ºC dew point)
MODEL | Port (inch) | Flow rate (m³/min) | Dimension (mm) | ||||
@5~6bar | @6~7bar | @7~10bar | L | W | H | ||
BTGMXW065-B | G2 | 4.8 | 5.8 | 6.5 | 451 | 240 | 1628 |
BTGMXW085-B | G2 | 6 | 7.4 | 8.5 | 560 | 240 | 1628 |
BTGMXW106-B | G2 | 7.4 | 9.1 | 10.6 | 668 | 240 | 1628 |
BTGMXW146-B | G2 | 9.8 | 12 | 14.6 | 885 | 240 | 1628 |
BTGMXW165-B | G2 | 11.6 | 14.2 | 16.5 | 994 | 240 | 1628 |
BTGMXW206-B | G3 | 14.6 | 17.8 | 20.6 | 763 | 480 | 1628 |
BTGMXW248-B | G3 | 16.7 | 20.5 | 24.8 | 794 | 480 | 1628 |
BTGMXW295-B | G3 | 21.5 | 26.3 | 29.5 | 903 | 480 | 1628 |
BTGMXW336-B | G3 | 24.1 | 29.5 | 33.6 | 1012 | 480 | 1628 |
BTGMXW385-B | G3 | 26.8 | 32.8 | 38.5 | 1121 | 480 | 1628 |
BTGMXW425-B | G3 | 29.7 | 36.4 | 42.5 | 1230 | 480 | 1628 |
BTGMXW465-B | G4 | 32.7 | 40.1 | 46.5 | 1339 | 480 | 1628 |
Standard working condition:Inlet pressure 0.7MPa≤P<1.0MPa,Temperature T≤35ºC;
Working condition:Pressure 0.4MPa≤P<1.0MPa,Temperature 2ºC≤T≤40ºC;
Technical date:Pressure dew point≤-40ºC
         Purge air≤5%
         Pressure drop≤0.012MP
         Noise≤75dB(average);
Â
B-series         Heat            (-40ºC dew point)
MODEL | Port (inch) | Flow rate (m³/min) | Dimension (mm) | Max Power | ||||
@5~6bar | @6~7bar | @7~10bar | L | W | H | Kw/1 Ph | ||
BTGMXD065-B | G2 | 4.8 | 5.8 | 6.5 | 451 | 240 | 1628 | 0.8 |
BTGMXD085-B | G2 | 6 | 7.4 | 8.5 | 560 | 240 | 1628 | 1 |
BTGMXD106-B | G2 | 7.4 | 9.1 | 10.6 | 668 | 240 | 1628 | 1 |
BTGMXD146-B | G2 | 9.8 | 12 | 14.6 | 885 | 240 | 1628 | 1.4 |
BTGMXD165-B | G2 | 11.6 | 14.2 | 16.5 | 994 | 240 | 1628 | 1.6 |
BTGMXD206-B | G3 | 14.6 | 17.8 | 20.6 | 763 | 480 | 1628 | 2 |
BTGMXD248-B | G3 | 16.7 | 20.5 | 24.8 | 794 | 480 | 1628 | 2.4 |
BTGMXD295-B | G3 | 21.5 | 26.3 | 29.5 | 903 | 480 | 1628 | 2.8 |
BTGMXD336-B | G3 | 24.1 | 29.5 | 33.6 | 1012 | 480 | 1628 | 3.2 |
BTGMXD385-B | G3 | 26.8 | 32.8 | 38.5 | 1121 | 480 | 1628 | 3.6 |
BTGMXD425-B | G3 | 29.7 | 36.4 | 42.5 | 1230 | 480 | 1628 | 4 |
BTGMXD465-B | G4 | 32.7 | 40.1 | 46.5 | 1339 | 480 | 1628 | 4.4 |
Standard working condition:Inlet pressure 0.7MPa≤P<1.0MPa,Temperature T≤35ºC;
Working condition:Pressure 0.4MPa≤P<1.0MPa,Temperature 2ºC≤T≤40ºC;
Technical date:Pressure dew point≤-40ºC
         Purge air: ≤2%
         Pressure drop≤0.012MP
         Noise≤75dB(average);
Â
Â
H finned tube is called square finned tube, there are two types of H finned tube, one is a single tube, usually called square finned tube, the other is a double tube, usually called rectangular finned tube. And according to customer requirements manufacturing. Due to its rectangular shape, it provides a larger surface area than spiral finned tubes. Because of the larger surface area available, these finned tubes are primarily used in air heating applications to reduce the overall size of the equipment.
H-shaped finned tubes have a high area expansion rate, less dust accumulation, and high heat transfer efficiency. In the case of equivalent heat transfer capacity, the heat exchanger can occupy the smallest space, and can minimize high-grade materials (ie, pressure tubes) The amount of use, and more use of low-grade materials,( 1919113,fins). For new engineering projects, the height of the heat exchanger arrangement can be reduced, the overall weight is greatly reduced, the load of the suspension system is reduced, and the overall cost is reduced; for the renovation project, as much heat exchange area as possible can be arranged in a limited space to reduce the exhaust temperature , Improve the efficiency of waste heat recovery or increase the maintenance space for easy maintenance.
Square Steel Pipe,Seamless Square Tubing,Square Galvanized Pipe,Seamless Square Steel Tube
Murphy Thermal Energy Co., Ltd. , https://www.murphyfinnedtube.com