4we5 Electrically Operated Directional Control Valves

Model NO.: 4WE5J61/CG24N9Z5L
Power Supply: DC Solenoid Valve
Usage: Emptying
Standard: DIN
Application: Industrial Usage, Water Industrial Usage, Household Usage
Nodular Cast Iron: Qt500
Size: Ng25
Trademark: Power or OEM
Transport Package: Carton
Specification: ISO9001
Origin: China
HS Code: 84812010
Model NO.: 4WE5J61/CG24N9Z5L
Power Supply: DC Solenoid Valve
Usage: Emptying
Standard: DIN
Application: Industrial Usage, Water Industrial Usage, Household Usage
Nodular Cast Iron: Qt500
Size: Ng25
Trademark: Power or OEM
Transport Package: Carton
Specification: ISO9001
Origin: China
HS Code: 84812010
Directional valve with wet pin solenoids, type WE5...
Type WE 5 directional valves adopt wet pin AC or DC solenoid to control different position of the spool valve.
The directional valves mainly consist of housing (1), one or two solenoids (2), the control spool (3), one or two return springs (4) and so on.
When solenoid is de-energised, the control spool (3) is maintained in its central position or initial position (except for impulse spool). The control spool is controlled by the wet pin solenoid (2).
To guarantee satisfactory operation care should be taken to ensure that the solenoid pressure chamber is filled with oil.
The control spool (3) is moved to the expected position by solenoid (2) and pushing rod (5), and this gives free-now from P to A and B to T or P to B and A to T.
When solenoid (2) is de-energised, the control spool (3) is pushed to the initial position by the return spring (4).
The solenoids may also control the control spool (3) by an optional override button (6) under the de-energised condition.

4we5 Electrically Operated Directional Control Valves4we5 Electrically Operated Directional Control Valves4we5 Electrically Operated Directional Control Valves4we5 Electrically Operated Directional Control Valves4we5 Electrically Operated Directional Control Valves
Directional valve with wet pin solenoids, type WE5...
Type WE 5 directional valves adopt wet pin AC or DC solenoid to control different position of the spool valve.
The directional valves mainly consist of housing (1), one or two solenoids (2), the control spool (3), one or two return springs (4) and so on.
When solenoid is de-energised, the control spool (3) is maintained in its central position or initial position (except for impulse spool). The control spool is controlled by the wet pin solenoid (2).
To guarantee satisfactory operation care should be taken to ensure that the solenoid pressure chamber is filled with oil.
The control spool (3) is moved to the expected position by solenoid (2) and pushing rod (5), and this gives free-now from P to A and B to T or P to B and A to T.
When solenoid (2) is de-energised, the control spool (3) is pushed to the initial position by the return spring (4).
The solenoids may also control the control spool (3) by an optional override button (6) under the de-energised condition.

4we5 Electrically Operated Directional Control Valves4we5 Electrically Operated Directional Control Valves4we5 Electrically Operated Directional Control Valves4we5 Electrically Operated Directional Control Valves4we5 Electrically Operated Directional Control Valves

Pneumatic Solenoid Valve

Solenoid valve is an industrial equipment controlled by electromagnetism. It is an automatic basic component used to control fluid. It belongs to actuator. Pneumatic solenoid valve is one of them. It blocks or leaks different oil drain holes by controlling the movement of valve body. The oil inlet hole is normally open, and hydraulic oil will enter different oil drain pipes, Then the oil pressure of the pneumatic solenoid valve pushes the piston of the oil cylinder. In this way, the mechanical movement of the whole solenoid valve is controlled by controlling the current of the electromagnet of the pneumatic solenoid valve.

Characteristic

It can work normally under vacuum, negative pressure and zero pressure, but its diameter is generally less than 25 mm.

It can also operate under zero pressure difference, vacuum and high pressure, but it has high power and must be installed horizontally.

The upper limit of fluid pressure range is high, which can be installed arbitrarily (need to be customized), but the condition of fluid pressure difference must be met.

Principle editing voice

There is a closed cavity in the pneumatic solenoid valve, and there are through holes in different positions. Each hole of the pneumatic solenoid valve leads to different gas pipes. There is a valve in the middle of the cavity and two electromagnets on both sides. The valve body will be attracted to which side when the magnet coil is electrified;

The pneumatic solenoid valve blocks or leaks different exhaust holes by controlling the movement of the valve body, and the air inlet is normally open. High pressure gas will enter different exhaust pipes, and then push the piston of the cylinder through the air pressure of the pneumatic solenoid valve. In this way, the mechanical movement of the whole solenoid valve is controlled by controlling the current of the electromagnet of the pneumatic solenoid valve.

Operation principle of pneumatic solenoid valve

We said the pneumatic solenoid valve working position (solenoid valve on or off), in fact, refers to the pneumatic solenoid valve spool position.

Pneumatic Solenoid Valve, Pneumatic Air Solenoid Valve, Electronic Solenoid Air Valve

Glove Industry Co.,Ltd. , https://www.glovemech.com