Item | parts | Material | ||
1 | Body | ASTMÂ A351Â CF8M | ASTMÂ A351Â CF8 | ASTMÂ A216Â WCB |
2 | Cap |
TMÂ A351Â CF8M |
ASTMÂ A351Â CF8 | ASTMÂ A216Â WCB |
3 | Ball | ASTMÂ A351Â CF8M | ASTMÂ A351Â CF8 | ASTMÂ A351Â CF8 |
4 | Seat | R-PTFE | R-PTFE | R-PTFE |
5 | Stem | ASTMÂ A182Â F316 | ASTMÂ A182Â F304 | ASTMÂ A182Â F304 |
6 | Thrust Washer | R-PTFE | R-PTFE | R-PTFE |
7 | Packing | PTFE | PTFE | PTFE |
8 | Gland | 304 | 304 | 304 |
CLASS | PRESSURE(MPa) | ||
(PN) | (Class) | Shell test | Seal test |
1 | - | 1.5 | 1.1 |
1.6 | - | 2.5 | 1.76 |
2.5 | - | 3.8 | 2.75 |
4 | - | 6 | 4.4 |
6.4 | - | 9.6 | 7.04 |
- | 150 | 3 | 2.2 |
- | 300 | 7.6 | 5.6 |
- | 600 | 15 | 11 |
- | 10K | 2.4 | 1.5 |
- | 20K | 5.8 | 4 |
Main external and connection dimension | ||||||||||||
PN1.6Â Mpa | ||||||||||||
DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 |
L | 130 | 140 | 150 | 165 | 180 | 200 | 220 | 250 | 280 | 320 | 360 | 400 |
H | 59 | 63 | 75 | 85 | 95 | 107 | 142 | 152 | 178 | 252 | 272 | 342 |
W | 130 | 130 | 160 | 180 | 230 | 230 | 400 | 400 | 650 | 1050 | 1050 | 1410 |
Wt(Kg) | 2.5 | 3 | 5 | 6 | 7 | 10 | 15 | 19 | 33 | 58 | 93 | 160 |
PN2.5Â Mpa | ||||||||||||
DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 |
L | 130 | 140 | 150 | 165 | 180 | 200 | 220 | 250 | 320 | 400 | 400 | 550 |
H | 59 | 63 | 75 | 97 | 107 | 142 | 152 | 178 | 252 | 272 | 342 | 345 |
W | 130 | 130 | 160 | 230 | 230 | 400 | 400 | 700 | 1100 | 1100 | 1500 | 1500 |
Wt(Kg) | 2.5 | 3 | 5 | 6 | 7.5 | 10 | 15 | 20 | 33 | 60 | 93 | 175 |
PN4.0Â Mpa | ||||||||||||
DN | 15 | 20 | 25 | 32 | 40 | 50 |
Cabinet Type Air Handling Unit
Face the air intake opening, if the pipe connection and service panel are on the left side, the unit will be considered as left connection, otherwise will be right side.
Characteristics: 1.Air handing unit applies colorful steel and galvanized panel as its interior and exterior panel. Inner stuff is the high density polyurethane foam,double pillar and tenon structure that ensures the strength of the unit and low air leakage. 2.High efficiency and low resistance nylon filter that reduce the power consumption obviously. Easy cleaning and simple operation; at the same time, higher level panel filter is optional too. 3.Coil applies pure and seamless copper tube and hydrophilic aluminum fin. Copper tube is under 12MPa water pressure expanding that can adapt to all kind of high pressure and no leakage, as well as ensure the lowest contact thermal resistance and highest heat transfer efficiency. 4.All fans in the unit are selected by professional software to ensure the best condition. Minimize the air volume and air pressure loose after meeting with the customer's requirements. Also ensure the good airflow and reduce the air duct noise. 5.Cabinet type air handling unit wish small size, low noise. It is widely applied in the comfortable Air Conditioning system such as the hostel, commercial building, office and underground railway application.
Cabinet Type Air Handling Unit Cabinet Type Air Handling Unit,Air Handling Unit Components,Air Handling Unit Diagram,Cabinet Type Air Handling Unit Jinan Amrta Air Conditioning Co.,Ltd , https://www.waterchiller.pl |